Standard Utility Details
To aid contractors, developers, and engineering firms in meeting the City of Mount Dora's codes for utility design and construction, the Engineering Division publishes the following Standard Utility Details.
These details can be downloaded three ways:
This site should be checked for each project as these details may be updated without notice.
General Number Definition
Each Standard Detail is numbered as XX000-9, where:
-
XX is two alphabetic characters describing the broad category for the detail
-
000 is a three digit number referring to the detail’s sequence, and
-
9 is a one-digit number representing the details’ relative revision status
The following are the two alphabetic characters that are used:
GU - General Utilities
PW - Potable Water
RW - Reclaimed Water
SS - Sanitary Sewer
Rules and Procedures for Electric Service
Specifications
Standard Document Templates
The revision number of any detail can be deduced from the suffix number following each standard detail; example Sanitary Sewer Detail SS002-1 is the detail for a Typical Sewer Connection, "SS002" will always be associated with this particular detail. The suffix number "-1" is used to identify the edition of this detail, revisions to the detail would result in the next number "-2" (SS002-2). Please do not remove the detail borders or numbering systems when incorporating the details into your plan set, having the numbers on the details allows us to quickly determine if your details are up-to-date.
If you have questions or problems with this site, please contact Mark Rudowske, Project Administrator, at (352) 735-7155 or 7151.
GU - General Utilities
(ZIP file: 3.44 MB)
| Number |
Title |
| GU001-1A |
Standard Construction Detail, General Notes |
| GU001-3B |
Standard Construction Detail, General Notes |
| GU001-1C |
Standard Construction Detail, General Notes |
| GU001-1 |
Manhole Frame and Cover |
| GU002-1 |
Pipe Identification |
| GU003-1 |
Utility Pipe Location Materials |
| GU004-2 |
Tracing Wire Connection |
| GU005-2 |
Valve, Valve Box and Cover |
| GU006-1 |
Utility Pipe Minimum Separation Requirements Table |
| GU007-1A |
Utilty Pipe Minimum Separation Requirements |
| GU007-1B |
Utility Pipe Minimum Separation Requirements |
| GU008-1 |
Bore and Jack for Water Service Connection |
| GU009-1 |
Line Flushing Assemblies |
| GU010-1 |
4-Inch Flushing Valve Assembly |
| GU011-1 |
Open Cut Detail |
PW - Potable Water
(ZIP file: 3.87 MB)
| Number |
Title |
| PW001-1A |
Standard Construction Detail, General Notes: Water |
| PW001-1B |
Standard Construction Detail, General Notes: Water |
| PW001-1C |
Standard Construction Detail, General Notes: Water |
| PW002-1 |
Standard Fire Hydrant Assembly |
| PW003-1 |
Fire Hydrant Color Identification |
| PW004-4 |
Potable Water - Single Service Connection |
| PW005-3 |
Potable Water - Double Service Connection for 3/4" & 1" Meters |
| PW006-3 |
Potable Water - Single Service Connection for 2" & Larger Meters |
| PW007-1 |
Master Meter Assembly with By-Pass & Reduced Pressure Backflow Prevention Assembly (RPBA) |
| PW008-1 |
Termporation Meter Installation |
| PW009-1A |
Temporary Jumper Connection Notes (Page 1) |
| PW009-1B |
Temporary Jumper Connection Detail (Page 2) |
| PW010-1 |
Potable Water Individual Above Ground Meter Set |
| PW011-2 |
Potable Water Standard Details |
RW - Reclaimed Water
(ZIP file: 2.59 MB)
| Number |
Title |
| RW001-1A |
Standard Construction Detail, General Notes: Reclaimed Water |
| RW001-1B |
Standard Construction Detail, General Notes: Reclaimed Water |
| RW002-2 |
Reclaimed Water Single Service Connection |
| RW003-2 |
Reclaimed Water Double Service Connection |
| RW004-2 |
Reclaimed Water Service Connection Box |
| RW005-1 |
Reclaimed Water Master Meter Assembly |
| RW006-2 |
Reclaimed Water Commercial Single Service Connection |
| RW007-2 |
Reclaimed Water Details, City Project |
| RW008-1 |
Reclaimed Water Signs |
SS - Sanitary Sewer
(ZIP file: 4.82 MB)
| Number |
Title |
| SS002-2 |
Typical Sewer Connection |
| SS003-1 |
Standard Manhole Detail |
| SS004-1 |
Typical Manhole Connections |
| SS005-1 |
Double Compartment Grease Trap & Inspection Sampling Station |
| SS006-2 |
Air Release Valve Assembly |
| SS007-4A |
Pump Station Details, Plan, Section and Notes |
| SS007-3B |
Pump Station Site Plan |
| SS007-2C |
Pump Station Control Panel Installation Detail |
| SS007-3D |
Duplex Control Panel Enclosure Dead Front Layout |
| SS007-3E |
Duplex Control Panel Enclosure Subpanel Layout |
| SS007-2F |
Chain Link Fence Detail |
| SS007-3G |
RTU Tower (125 MPH Wind) |
| SS008-2 |
Sanitary Sewer Details, City Projects |
Electric Service
Rules and Procedures for Electric Service
Specifications
(ZIP file: 59.9 KB)